Solar Heat, Water Beat: Your Eco-Friendly Duo
  • Home
  • About us
  • Shop
  • Blog
  • Contact us
Login / Register
Wishlist
0 items / ₨ 0.00
Menu
0 items / ₨ 0.00
-33%
Click to enlarge
Home Heat Pump Osmo 250L Heat Pump (Water Heater 220V, 3500W)
Kent ACE ₨ 37,290.00 ₨ 29,500.00
Back to products
Osmo 500L Heat Pump (Water Heater System 220v 5000W) ₨ 450,000.00 ₨ 360,000.00
Osmo

Osmo 250L Heat Pump (Water Heater 220V, 3500W)

₨ 390,000.00 ₨ 260,000.00

https://solarwaternepal.com/wp-content/uploads/2025/03/OSMO-HEATPUMP.mp4
Compare
Add to wishlist
Category: Heat Pump
Share:
  • Description
  • Additional information
  • Reviews (0)
Description

Osmo 250L Heat Pump Water Heater (220V, 3500W)

The Osmo 250L Heat Pump Water Heater is an energy-efficient, high-performance water heating solution designed for modern homes and businesses. With a 250L capacity, it provides ample hot water to meet your daily needs while ensuring low energy consumption. This heat pump system operates on 220V power with a 3500W capacity, delivering reliable and consistent heating performance.

Technical Specification of Air source heat pump system.

  1. System Type:
    • -Its an air-source heat pump system.
  1. Capacity and Efficiency:
    • Tank capacity –250L
    • Desired efficiency ratings – max outlet water temp 60ºC
  1. Refrigerant:
    • R22 standard
  1. Components:
      • Indoor and outdoor units.—-included
      • Heat exchangers.————–included
      • Compressor type —–Valley wheel compressor
      • Control system.—————-included
      • Air handling unit.————–included
      • Defrosting mechanism.——-included
      • Noise reduction features.—–included
  1. Performance Requirements:
    • Temperature control parameters.—55℃-60℃
    • Defrosting mechanisms and strategies.-It adopts hydrophilic corrugated high-efficiency evaporator, which has excellent hydrophilic performance and can quickly discharge condensed water and reduce frosting. At the same time, the corrugated sheet evaporator has a large evaporation area and higher heat exchange efficiency.
    • Noise level requirements for both indoor and outdoor units.–≤52dB(A)
    • Energy consumption targets.-  1300W for 2.5KW ,
    • Compatibility with existing HVAC systems or infrastructure.–Compatible
  1. Installation Requirements:
    • Electrical requirements (voltage, phase, current).—-220V/50HZ
    • Physical space considerations for indoor and outdoor units.–1.The area around the unit should be kept dry, clean and well ventilated. 2. Do not place any objects at the fan discharge port to avoid poor air exhaust. 3. There must be no obstructions within 0.3 meters outside each air inlet to prevent the air from being blocked.
    • smooth.
  1. Maintenance:
    • Recommended maintenance tasks and schedules for optimal performance.-Once per year.
    • Filter replacement frequency.-Once per year.
    • Inspection intervals for components such as coils, fans, and compressors.-Once per year.

Things to note when using air source heat pump systems

  1. Before starting the machine, check that the power supply specifications on the nameplate must match the actual power supply.
  2. After the unit is started, the operating voltage must be measured. If the voltage is unstable, a voltage stabilizer must be installed.
  3. The air in the pipeline must be drained, otherwise it will lead to abnormal circulation and high-pressure failure.
  4. The area around the unit should be kept dry, clean, and well ventilated.
  5. The unit radiator should be cleaned once a year to maintain good heat dissipation effect.
  6. A water filter must be installed for the water inlet of the unit to prevent debris from clogging the heat exchanger.
  7. Do not place any objects at the fan discharge port to avoid poor ventilation.
  8. There should be no obstructions within 0.3 meters outside each air inlet to avoid poor air intake.
  9. Do not put sticks and other objects into the wind wheel mouth, and do not step on or sit on the machine casing.
  10. Do not cut off the power supply during short-term shutdown in winter so that the unit can activate the anti-freeze function.
  11. If the unit is installed in a place prone to lightning strikes, be sure to take lightning protection measures.
  12. If the ambient temperature is lower than -2℃ and the unit needs to be stopped, the water in the heat exchanger should be drained to avoid freezing and cracking of the unit pipelines. If the unit is damaged as a result, it will not be covered by the warranty.

Things to note when installing air source heat pumps system

  1. Operation and maintenance management of collectors

Antifreeze: Keep water flowing when the ambient temperature is 5°C lower: keep the heating tape started to prevent pipes from freezing and cracking; ensure that there is sufficient water temperature in the water tank to maintain active antifreeze requirements.

2 Maintenance: Regularly check whether the vacuum tube is damaged and replace it with a new one: regularly clean or flush the dust on the surface of the vacuum tube to ensure light transmittance.

Operation and maintenance management of water pumps

  1. Before operation: The water pump and water inlet pipe should be completely filled with water. During the water filling process, pay attention to exhaust.
  2. After operation: Check whether the rotation direction of the pump shaft is correct and whether the rotation of the pump shaft is flexible.
  3. During operation: Check whether the motor has an excessively high temperature, whether there is any odor, and whether there is abnormal sound and vibration. After the water supply and power are cut off, promptly check whether the water pump has air intake and exhaust.
  4. Maintenance: Clean and inspect the water pump once a year, replace the shaft seal as appropriate, remove rust and paint the surface of the pump body once a year, and check whether the rain cover of the water pump is damaged.

Operation and maintenance management of automatic control

  1. Parameter inspection: Maintenance and repair personnel regularly conduct patrols to check operating parameters, collector temperature, return water temperature, antifreeze temperature, water tank temperature, water tank water level, water pump and electric cargo valve switching status, etc., and understand the collector through monitoring Check whether it is overheated or frozen, find out if there is a fault in time, and eliminate hidden dangers in a timely manner.
  2. Data summary: Save the data recorded manually every time, and summarize the data regularly and bind it into a book.
  3. Maintenance: Check whether the connecting wires are damaged or aged, whether the welding points are open or weak, whether the fastening screws are loose, and whether the connecting terminals are oxidized.
  4. Operation, maintenance and management of electric pavement heating

1 Before operation: Check whether the water tank has sufficient safe water level, and the opening and closing status of the power circuit breaker and AC contactor are correct.

2 Maintenance: Check whether there is scale on the electric heater, whether the wires are aged, whether the connections are loose, etc.

Maintenance of pipelines, water tanks and accessories

1 Regularly check whether the pipe insulation layer is damaged to ensure the insulation of the pipe:

  1. Check the sealing and scaling of the water tank, repair and remove them in time:
  2. Keep the valve clean to prevent rust and seizure, and repair and replace it in time if there is any problem.

 

Additional information
Brand

Osmo

Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “Osmo 250L Heat Pump (Water Heater 220V, 3500W)” Cancel reply

Your email address will not be published. Required fields are marked *

Related products

-24%
Compare
Quick view
Add to wishlist
Add to cart

Osmo 1000Ltr Heat Pump (Water Heater System 220v 10000W)

Heat Pump
₨ 850,000.00 ₨ 650,000.00
-20%
Compare
Quick view
Add to wishlist
Add to cart

Osmo 500L Heat Pump (Water Heater System 220v 5000W)

Heat Pump
₨ 450,000.00 ₨ 360,000.00

solar_logo-removebg-preview

Explore our store and discover a harmonious blend of modern design and sustainable living.

  • Kathmandu, Nepal
  • Phone: 986-0711764
  • Email: nthapa003@gmail.com
Recent Posts
  • IMG-20250922-WA0005
    Tesla Megapack Battery Specifications and Capacity Details
    January 4, 2026 No Comments
  • Exhaust-Fan-vs-Modern-Kitchen-Chimney
    Highlighting Difference Between Modern Kitchen Chimney and an Exhaust Fan
    December 30, 2025 No Comments
Useful Links
  • Privacy Policy
  • Terms & Conditions
  • Latest News
  • Contact us
Quick Links
  • Home
  • About us
  • Shop
Solar Heater and Water Filter Traders 2024 CREATED BY Mandala Infosys.
  • Menu
  • Categories
  • Kitchen Chimney
  • Water Treatment Plant Nepal
  • Water Heater Nepal (Solar)
  • Gas hub cooktop
  • Water Filter nepal (RO Purifier)
  • Gas Electric Geyser
  • Heat Pump
  • Parqueting
  • Home
  • About us
  • Shop
  • Blog
  • Contact us
  • Wishlist
  • Compare
  • Login / Register
Shopping cart
close

Sign in

close

Lost your password?

No account yet?

Create an Account
Start typing to see products you are looking for.
Shop
Wishlist
0 items Cart
My account